ASTM D3330 EPUB

31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Akigami Shakaramar
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Photos
Published (Last): 6 January 2007
Pages: 311
PDF File Size: 13.82 Mb
ePub File Size: 8.64 Mb
ISBN: 269-9-37779-211-4
Downloads: 42802
Price: Free* [*Free Regsitration Required]
Uploader: Moogujar

The clamping force is all air operated giving more consistent test results, less work for the operator, less room for error, and is astm d3330 and easier for testing numerous samples.

ASTM D Peel Adhesion Pressure Sensitive Adhesive Tapes

If you would rather see the data in real-time and study astm d3330 peel interface at the same time, we would provide you with our XyLive Software. Record the average force required for peeling. The 25mm wide jaws are better for aligning smaller sample sizes.

Testing astm d3330 then conducted for degree peel adhesion. Apply a second strip of the tape to the backing of the first strip on the e3330 panel, taking care to align the edges of the astm d3330 specimen with those astm d3330 the strip in the test panel. For this test we recommend that care be taken in aligning the grips to prevent the backside of the tape specimen from rubbing. ASTM D Test Method D provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape.

ASTM D3330 Peel Adhesion of Pressure Sensitive Tape How to Guide

Forces up to 10 kN aastm, lbf Low astm d3330 tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, astm d3330, peel and much more. For complete instructions and ensuring that astm d3330 products are in accordance with ASTM D, please refer to the official specification in the relevant ASTM publication. The data from this test measures the uniformity of adhesion of a pressure sensitive tape.

Fold back the tab to a 90 degree angle and connect it to the grip.

We are confident that we have what you are looking for. Two different astm d3330 seldom astm d3330 in these properties. Test Methods A, B, C, E or F cannot be used to compare two pressure-sensitive tapes of the same type but of different manufacture for their asmt to adhere to a surface.

In a liner-side application, the transfer tape is applied to a strip of 0. Remove the liner and tape the polyester film in dd3330 place. Asfm D Method F measures the astm d3330 of single-coated tapes to a standard steel panel or your chosen substrate when peeled at a 90 degree angle. Begin peeling the tape at a 90 degree angle. Rated to 1 kN lbf Maximum specimen thicknesses from 10 mm to 50 mm 0. The liner is removed and the exposed adhesive covered with a strip of thin polyester film.

Repeat steps 1 to 6 of Test Method A. Next, clamp astm d3330 substrate panel into the moveable jaw of testing machine and free end of tape into other jaw.

Now apply a strip of d33300 tape to a rigid panel, such as the standard stainless steel panel. G Series Mechanical Vice Grip.

GK Mechanical Vice Grip. These test methods are tools for quality assurance use. Create astm d3330 tab with lining and complete the test by repeating the steps of test method A on the lining. Move the plate and begin peeling the tape at a degree angle at the specified rate. Secure the end astm d3330 the plate furthest away from the tab to the moving grip.

The tape is peeled from the panel at 90 degree angle at a constant speed, during which time the force required to effect peel is measured. Historical Astm d3330 s – view previous versions of astm d3330.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

Test Method D can show the amount of force required to remove a liner that covers the adhesive side of a tape at a specified peel rate.

Adhere the tape specimen onto the test panel using a astm d3330 roller. This plot will be an important astm d3330 of data retrieval and therefore astm d3330 highly recommend our XyPlot software. Although we can provide you with guidance, we recommend you purchase and closely follow the ASTM International testing standard. They can help you configure the best test machine and grips for your specimens.

ASTM D Test Method D gives a measure of the adherence of the release liner to the adhesive of either single- or double-coated tape.

The liner is peeled from the adhesive in the astm d3330 manner as in peeling a single-coated tape astm d3330 a standard panel. A strip of tape is applied to a standard test panel that with controlled pressure from a TestResources Sample Roller.

ASTM D3330 Peel Adhesion Pressure Sensitive Adhesive Tapes

It is also important to align the astm d3330 perpendicular in the grips so that the peel line is straight across. For Method B, measure out astm d3330 strips of the tape according to the standard. Fold a c3330 of the tape and double back at an angle of degrees.

The purpose of ASTM D data results help assess the uniformity of adhesion for pressure sensitive tapes.

It is the responsibility of the astm d3330 of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.